Add to Cart
Description
IEC 62660-2 130℃ Battery Temperature Cycling Test Chamber are suited for testing battery reliability under extreme temperature changes.
Battery need to be able to withstand drastic changes in temperature.
The thermal shock and temperature cycling tests called out in the IEC, UL, and SAE standards
Technical Specification
Name | IEC 62660-2 130℃ Battery Temperature Cycling Test Chamber |
Model | TK10-220 |
Internal Dimension (mm) | 500*600*750 |
Overall Dimension (mm) | 960*1150*1860 |
Temperature Range (℃) | -70℃ ~+150 ℃ |
Cooling Rate | 10℃/min (15℃/min) |
Heating rate | 10℃/min (15℃/min) |
Temperature Fluctuations | ± 0.5 ℃ |
Temperature Deviation | ± 2.0 ℃ |
Interior Volume | 220 liters |
Controller | Programmable color LCD touch screen controller, Multi-language interface, Ethernet , USB |
Cooling System | Mechanical compression refrigeration system |
Exterior Material | Steel Plate with protective coating |
Interior Material | SUS304 stainless steel |
Power Supply | 380V |
Maximum Noise | 65 dBA |
Thermal Test
Battery Temperature Cycling Test Chamber,This test is performed to characterize cell responses to high-temperature environment.
a) Adjust the SOC of the cell to 100% for BEV application, and to 80% for HEV application.
b) The cell, stabilized at room temperature, shall be placed in a gravity or circulating air convection oven. The oven temperature shall be raised at a rate of 5K/min to a temperature of 130℃±2K. The cell shall remain at this temperature for 30 min before the test is discontinued.
![]() | Note: If necessary, to prevent deformation, the cell may be maintained during the test in a manner that does not violate the test purpose. The manner to prevent deformation should be representative of cells inside battery systems and battery packs.
IEC 62660-2 130℃ Battery Temperature Cycling Test Chamber |
Test Standard
1. IEC 62660-2:The oven temperature shall be raised at a rate of 5K/min to a temperature of 130℃±2K.
2. IEC 62133 - Temp cycling: 75 to 20 to -20°C (30 min. transitions)
3. UL 2054 - Temp cycling: 70 to -40 °C (30 min. transitions)
4. UL 1642 - Temp cycling: 70 to 20 to -40 °C (30 min. transitions)
5. SAE J2464 - Thermal shock test: 70 to -40°C (15 min. transitions)
■ The LIB Battery Temperature Cycling Test Chamber meet IEC 62660-2 standard for test battery